Page 11 of European Technical Approval ETA-11/0390, issued on 27.08.2012
English translation prepared by CSTB
 
 
 
 
 
 
of  the European
Technical Approval
 
ETA - 11/0390
Injection System Hilti HIT-CT 1 for rebar connection
 
Product description and intended use
The post-installed rebar connection consists of injection mortar Hilti HIT-CT 1 and an embedded
straight deformed reinforcing bar with properties of class B and C according to Annex C of EC 2 or
the Hilti tension anchor HZA-R.
 
 
Injection mortar HIT-CT 1
 
 
 
 
 
 
 
 
Static mixer  
 
 
 
 
Reinforcing bar according to EC 2 (see Annex 4):
 
 
 
Hilti Tension anchor HZA-R (see Annex 6):
 
 
 
 
 
Covered are post-installed rebar connections in non-carbonated concrete on the assumption only
that the design of post-installed rebar connections is done in accordance to EC2.
Installation in dry or wet concrete, it must not be installed in flooded holes.
 
Temperature range: -40°C to +80°C
(maximum long term temperature +50°C and maximum short term temperature +80°C)
 
 
 
Annex 1
 
Product description and intended use
 
Foil pack:
330 ml and 500 ml
 
 
HIT-CT 1